With rubber support padded on board. 100(L)X88(W) mm.
No abnormal when powered with500VAC for. When powered with 250VAC, insulation. Magnetic pole position inspection method. 4.2.1 cooling performance. 4.2.2 Noise level.^Remark: Noise sensor locate at 15cm above compressor. 0.281±0.005 Mpa(A).
High pressure switch setting (gauge pressure). =2.5MPa cut off, 2.45MPa recovery(depend on customer).Low pressure switch setting (gauge pressure). =0.1MPa cut off, 0.23MPa recovery(depend on customer). Main power supply voltage should be less than. Otherwise, the internal device of the controller will be.
Compression bolt torque of compressor suction vent is 11. Compressor body not to be tilted the angle between the main axis of the compressor and the horizon should not be. Electric compressors should be avoided from being installed.At the outlet of the condenser to ensure adequate cooling of. Compressor needs refrigerant cooling motor and controller. Suction pipe should be added insulation pipe. Suggest the compressor start 6 seconds before opening the. Condenser fan, after the compressor stops, the condenser.
Fan shuts off for 30 seconds. To prevent the system entering too much moisture and. Causing insulation to drop off, the compressor suction outlet. Should be installed in a closed system immediately after. Compressor should be installed with damping pad to achieve. The purpose of vibration reduction and noise reduction.1 x Brushless controller unit. 1 x Power wire1 x Evaporator wire. 1 x Cooling fan extension lines. Ines Electric fan and drier are not including!
Air conditioner compressor designs that split control panel from the main body. For clear to see the wire connected to the fan, evaporator, condenser, power supply. Easy to check any fault at running. Control panel apply Brushless controller unit with LED Blinking hint and protection mode.LED Blinking hint is special designs for the fault. During the using, some irreguar operate lead to some wrong like, Excessive current, Underv.
Oltage, Locked rotor, Standby mode, over heated, over preasure. This Air conditioner compressor will turn to protection mode and hint by LED blinking. Blinking 1 times, pause 1 second: Standby mode. Fast blinking 2 times, pause 1 second: Excessive current, Over 50A. Fast blinking 3 times, pause 1 second: Locked rotor protection.
Fast blinking 4 times, pause 1 second: Undervoltage protection. Fast blinking 6 times, pause 1 second: Electric fan fault. Fast blinking 7 times, pause 1 second: Motor lack of phase. Please check if the motor got burnt and connection is correct or not. Fast blinking 8 times, pause 1 second: Compressor over heated protection. Fast blinking 9 times, pause 1 second: Pressure switch protection.All items are real stocked locally in our warehouse. We process orders fast with 98% of items dispatched within 24 hours. If logistics shows delivers but nothing sign for, contact without hestation, will help track the details and wait for investigation. Wrong address---If shows delivered we will try to retrieve package no guarantee. Dear Friend, we must be notified within 30 days after you receive products, and must not use, the products in good condition, does not affect the second sales situation along with all labels and packaging to return.
We focus on the production and development of new energy air-conditioning systems. We have a professional technical team and after-sales team. We can help you solve any after-sales problems in a timely manner.